Pump Unit#3 pump curve weight GVW 6640kg Brochure
This FMC triplex pump facility is rated for continuous 15m^3/hour (360m^3/day @6300kPa)
SCADA equipped for remote control and viewing
PLC touch screen for easy settings and controls
Pump area zoned Class 1, Div 2, Power generator un-classified.
Completely automated shutdown with remote sensors through out.
Beacon lights to show status of pump operation
All piping is NACE
Equipped with on-board generator for standalone operations
Pump motor is VFD operated; speed pot used to control pump speed
Easy to use interface with Stop & Go buttons, Speed Pot and Emergency shutdown.
Chemical pump#1 weight GVW 4000 kg
Milton Roy C pump, positive displacement, is capable of injection rates from nominal to over 2 litres per minute at upwards pressures of 21,300 kPa
This unit is a stand-alone. The diesel generator comes with a positive air shut-down system and emergency kill-switch. Unit can also plug into existing power on site; 30 Amp/ 220 volt 3 phase.
Features:
-Stainless stell DOT certified Tote Tank (1.3 cubic meter)
-An easy to use VFD system with stop / go buttons and speed pot for variable rate control
-Volume totalizer display in mililitres
-Field set back pressure valve; discharge into suction
-PSV set for maximum pump pressure discharge into tank
-Reservoir Tote tank is sealed and vented outside
-Stainless steel manifold and pump end parts
Pump Unit #1 pump curve weight GVW 5990 Kg Brochure
This FMC triplex pump facility is rated for continuous 9.0m^3/hour (216m^3/day @9650kpa)
Pump area zoned Class 1, Div 2, Power generator un-classified.
Completely automated shutdown with remote sensors through out.
Beacon lights to show status of pump operation
All piping is NACE
Equipped with on-board generator for standalone operations
Pump motor is VFD operated; speed pot used to control pump speed
Easy to use interface with Stop & Go buttons, Speed Pot and Emergency shutdown.
Pump Unit#5 pump curve weight GVW 6040 kg
This is a multi-stage Grundfos centrifugal pump rated for continuous 60m^3/hour (1440m^3/day @2MPa) unit good for 2.9MPa
Pump area zoned Class 1, Div 2, Power generator un-classified.
Completely automated shutdown with remote sensors through out.
Beacon lights to show status of pump operation
All piping is NACE
Equipped with on-board generator for standalone operations
Pump motor is VFD operated; speed pot used to control pump speed
Easy to use Stop & Go buttons, Speed Pot and Emergency shutdown.
Pump Unit #2 pump curve weight GVW 6750 kg Brochure
This FMC triplex pump facility is rated for continuous 12m^3/hour (288m^3/day @7700kPa)
SCADA equipped for remote control and viewing
PLC touch screen for easy settings and controls
Pump area zoned Class 1, Div 2, Power generator un-classified.
Completely automated shutdown with remote sensors through out.
Beacon lights to show status of pump operation
All piping is NACE
Equipped with on-board generator for standalone operations
Pump motor is VFD operated; speed pot used to control pump speed
Easy to use interface with Stop & Go buttons, Speed Pot and Emergency shutdown.
Each pump unit is equipped with pressure control and precise fluid handling. All pump units are a closed system; no sour fluids are vented or released to atmosphere. The vent header is utilized in conjunction with the FMC vaporless stuffing box of the triplex pumps along with a scrubbing agent (supplied by customer).
Equipment comes with charge pumps to handle all scenarios:
click to download