Pump Unit#3 pump curve weight GVW 6640kg Brochure

This FMC triplex pump facility is rated for continuous 15m^3/hour (360m^3/day @6300kPa)

SCADA equipped for remote control and viewing

PLC touch screen for easy settings and controls

Pump area zoned Class 1, Div 2, Power generator un-classified.

Completely automated shutdown with remote sensors through out.

Beacon lights to show status of pump operation

All piping is NACE

Equipped with on-board generator for standalone operations

Pump motor is VFD operated; speed pot used to control pump speed

Easy to use interface with Stop & Go buttons, Speed Pot and Emergency shutdown.


Chemical pump#1 weight GVW 4000 kg

Milton Roy C pump, positive displacement, is capable of injection rates from nominal to over 2 litres per minute at upwards pressures of 21,300 kPa

This unit is a stand-alone.  The diesel generator comes with a positive air shut-down system and emergency kill-switch.  Unit can also plug into existing power on site; 30 Amp/ 220 volt 3 phase.

Features:

-Stainless stell DOT certified Tote Tank (1.3 cubic meter)

-An easy to use VFD system with stop / go buttons and speed pot for variable rate control

-Volume totalizer display in mililitres

-Field set back pressure valve; discharge into suction

-PSV set for maximum pump pressure discharge into tank

-Reservoir Tote tank is sealed and vented outside

-Stainless steel manifold and pump end parts

Pump Unit #1 pump curve weight GVW 5990 Kg Brochure


This FMC triplex pump facility is rated for continuous 9.0m^3/hour (216m^3/day @9650kpa)

Pump area zoned Class 1, Div 2, Power generator un-classified.

Completely automated shutdown with remote sensors through out.

Beacon lights to show status of pump operation

All piping is NACE

Equipped with on-board generator for standalone operations

Pump motor is VFD operated; speed pot used to control pump speed

Easy to use interface with Stop & Go buttons, Speed Pot and Emergency shutdown.

Pump Unit#5 pump curve weight GVW 6040 kg

This is a multi-stage Grundfos centrifugal pump rated for continuous 60m^3/hour (1440m^3/day @2MPa) unit good for 2.9MPa

Pump area zoned Class 1, Div 2, Power generator un-classified.

Completely automated shutdown with remote sensors through out.

Beacon lights to show status of pump operation

All piping is NACE

Equipped with on-board generator for standalone operations

Pump motor is VFD operated; speed pot used to control pump speed

Easy to use Stop & Go buttons, Speed Pot and Emergency shutdown.

Pump Unit #2 pump curve weight GVW 6750 kg Brochure

This FMC triplex pump facility is rated for continuous 12m^3/hour (288m^3/day @7700kPa)

SCADA equipped for remote control and viewing

PLC touch screen for easy settings and controls

Pump area zoned Class 1, Div 2, Power generator un-classified.

Completely automated shutdown with remote sensors through out.

Beacon lights to show status of pump operation

All piping is NACE

Equipped with on-board generator for standalone operations

Pump motor is VFD operated; speed pot used to control pump speed

Easy to use interface with Stop & Go buttons, Speed Pot and Emergency shutdown.

Each pump unit is equipped with pressure control and precise fluid handling.  All pump units are a closed system; no sour fluids are vented or released to atmosphere.  The vent header is utilized in conjunction with the FMC vaporless stuffing box of the triplex pumps along with a scrubbing agent (supplied by customer).  

Equipment comes with charge pumps to handle all scenarios:

click to download

-DeanLine

-Blackmer

-Flomax 8

-Flomax 30